| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | QSFP56-200G-AOC10M | |
| 2 | Arista Networks | A-Q200-Q200-10M | |
| 3 | HPE Aruba | QSFP56-200G-AOC10M | |
| 4 | Intel | QSFP56-200G-AOC10M | |
| 5 | NVIDIA/Mellanox | MFS1S00-V010E | |
| 6 | H3C | QSFP56-200G-AOC10M |
Key Technical Specifications
| NVIDIA/Mellanox Compatible |
MFS1S00-V010E
|
Vendor Name | HYTOPTODEVICE |
| Connector | QSFP56 to QSFP56 | Max Data Rate | 200Gbps |
| Operating Wavelength | 850nm | Fiber Cable | OM4 MMF |
| Cable Length | 10m (33ft) | Power Consumption | ≤4.5W |
| Host Required | FEC | Operation Temperature | 0~ 70 °C (32 to 158°F) |
| Minimum Bend Radius | 30mm | Protocols | IEEE 802.3, QSFP56 MSA, SFF-8665, SFF-8636 |
| Application |
200G-SR4 Ethernet
|
Warranty | 5 Years |
Usage Guidelines & Best Practices
For detailed operation instructions, please refer to the User Guide.
Full Compatibility List & Supported Devices
Built on universal MSA open standards, this 200g qsfp56 aoc active optical cable supports mixed-vendor networking hardware. It can interoperate with mainstream network brands including Arista, H3C, Juniper, Dell, NVIDIA Mellanox and more, suitable for mixed-vendor rack stacking and AI server fabric expansion.






Q1: Can QSFP56 AOC modules physically fit and work on QSFP-DD Ethernet ports? A: Yes. QSFP56 and QSFP-DD have distinct housing sizes and pin arrangements. This NVIDIA/Mellanox compatible 200g qsfp56 aoc factory cable cannot insert into QSFP-DD slots, a critical point for buyers planning mixed-form-factor Ethernet data center upgrades.
Q2: Is it possible to split this straight 200G Ethernet AOC into two separate 100G data channels? A: No. This is a non-breakout direct 200G AOC assembly for single-channel Ethernet. It transmits one unified 200G PAM4 Ethernet signal and cannot separate into two 100G links; contact HYTOPTODEVICE if you need breakout-style 200G AOC solutions for Ethernet.
Q3: Will this AOC trigger unknown module pop-up messages on NVIDIA Mellanox Ethernet switching platforms? A: It will not trigger warnings with our custom EEPROM programming service. HYTOPTODEVICE calibrates module information to match NVIDIA/Mellanox Ethernet platforms for this 200g qsfp56 aoc factory product, simplifying large-scale Ethernet rack deployment.
Q4: Is this MFS1S00-V010E compatible AOC engineered primarily for InfiniBand workloads? A: No. This MFS1S00-V010E compatible AOC is optimized for 200G PAM4 Ethernet networking. While it meets MSA electrical specs, its firmware and tuning target Ethernet data center workloads instead of InfiniBand.
Q5: Will this 200G QSFP56 AOC realize stable link when connecting Ethernet gear from different manufacturers? A: Yes. Designed around MSA open standards, this 200g qsfp56 aoc factory cable delivers stable cross-vendor interoperability to connect NVIDIA, Cisco, Arista, Dell and other compatible Ethernet hardware for multi-brand fabric builds.
Q6: How does the latency performance of QSFP56 AOC compare with DAC and standalone transceivers within Ethernet fabrics? A: AOC latency is slightly higher than DAC, roughly 5–10 ns. The small optical-electrical conversion delay is negligible for most Ethernet leaf-spine and AI server workloads, while this 10m AOC provides far longer reach than copper DAC alternatives.
Q7: What is the per-end power rating of this 200G AOC, and how does it stack up against other Ethernet AOCs on the market? A: Power consumption is 4.5W per end. Our HYTOPTODEVICE 200G QSFP56 AOC features optimized circuitry, delivering lower power consumption than many competing Ethernet AOC models to reduce rack heat load in dense server environments.
Q8: Can nearby power cables’ electromagnetic noise corrupt the Ethernet signal transmitted over this AOC? A: No. Data travels via light over glass fiber instead of copper conductors. This NVIDIA/Mellanox compatible AOC is fully EMI immune, making it suitable for routing near power supplies in high-density Ethernet server rack environments.
Q9: What rate can each individual lane support on this 200G QSFP56 Ethernet active optical cable? A: Each lane supports 50Gbps PAM4. Four parallel lanes combine to deliver the full 200G aggregate bandwidth of this 200g qsfp56 aoc factory cable for Ethernet compute and storage interconnections.
Q10: Do different OM4 AOC lengths create noticeable signal attenuation gaps for 200G Ethernet links? A: Optical loss rises marginally with length within OM4’s rated transmission range. The attenuation remains well within acceptable Ethernet link budgets; our 10m factory stock model maintains clean signals for cross-rack leaf-spine uplinks.
Q11: Why choose factory-built AOC instead of pairing two discrete 200G transceivers plus fiber patch cords for Ethernet deployments? A: Factory pre-terminated AOC reduces installation steps and potential failure points. For short-distance transmission runs below 30 meters, the AOC solution is highly recommended for Ethernet data center operators, and our HYTOPTODEVICE 200G QSFP56 AOC is a cost-effective factory option for bulk rollout.
Q12: When one transceiver head fails, can I replace only that damaged end rather than swapping the whole Ethernet AOC? A: No. The AOC is a sealed integrated optical assembly. If one transceiver end fails, the entire cable needs replacement. HYTOPTODEVICE maintains fast factory lead times for replacement orders of this 200g qsfp56 aoc factory cable for Ethernet networks.
Q13: What bending limit should installers follow when running this 200G AOC inside compact Ethernet server racks? A: The minimum bend radius is 30mm. Bending tighter than this threshold will create extra optical attenuation, installers must follow this specification during cabling for this 10m NVIDIA/Mellanox compatible Ethernet AOC.
Q14: How durable is the pull-tab latch under repeated hot swapping during Ethernet data center maintenance cycles? A: No. The pull tab is reinforced for repeated plug-and-unplug cycles. Our 200g qsfp56 aoc factory cable uses robust latch tabs to withstand regular hot swapping during Ethernet cluster maintenance.
Q15: How does the weight of long-run 200G AOC compare with twinax DAC of identical length for Ethernet cabling layouts? A: AOC is significantly lighter than equivalent twinax DAC. Optical fiber is much less dense than copper, so even longer AOCs cut port strain and streamline cable management in tall, densely packed Ethernet server racks.
Packaging & Custom OEM Solutions
ESD Protection & Fast Shipping: Every transceiver is sealed in an ESD-safe bag and ready for same-day dispatch from stock.
Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.