| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | DELL | 430-4593 | |
| 2 | EdgeCore | ET6401-SR4 | |
| 3 | Extreme | 10319 | |
| 4 | HPE Aruba | JH231A | |
| 5 | H3C | QSFP-40G-SR4-MM850 | |
| 6 | HPE BladeSystem | 720187-B21 | |
| 7 | HPE H3C | JG325A | |
| 8 | F5 Networks | F5-UPG-QSFP+ |
| HPE Aruba Compatible | JH231A | Vendor Name | HYTOPTODEVICE |
| Form Factor | QSFP+ | Max Data Rate | 41.25Gbps |
| Wavelength | 850nm | Max Distance | 150m@OM4/100m@OM3 |
| Connector | MTP/MPO | Transmitter Type | VCSEL 850nm |
| Cable Type | MMF | Receiver Type | PIN |
| TX Power | -8.0~1.0dBm | Receiver Sensitivity | < -13dBm |
| Power Consumption | ≤1.5W | Modulation | NRZ |
| Protocols | IEEE 802.3 40GBASE-SR4, SFF-8436 | Operation Temperature | 0 to 70°C (32 to 158°F) |
Usage Guidelines & Best Practices
Fiber Choice: Only compatible with OM3 / OM4 multi‑mode MPO‑12 trunk cabling; single‑mode fiber cannot facilitate 850 nm SR4 operation and will produce link failure.
Distance Limit: 100‑metre maximum operating reach on OM3, 150‑metre maximum on OM4; excessive splice joints, dirty connector end‑faces or sharp fiber bends degrade practical transmission distances.
Cleanliness & Dust: Keep dust caps on whenever unattached. Clean fiber end-faces with a optical cleaning pen before insertion; dust causes over 80% of optical link failures.
Installation Specification: Hot‑plug supported; keep MPO connector end‑faces clean, observe minimum fiber‑bend radius requirements.
Operating Environment: Designed for commercial‑grade 0°C‑70°C ambient conditions; maintain adequate cabinet‑level airflow to prevent excessive module temperature build‑up.
Full Compatibility List and Supported Devices
1. Supported Hardware & Firmware
Primary Application Scenarios
• Intra‑data‑center short‑distance leaf‑spine fabric links built on HPE Aruba switching hardware
• 40G aggregation‑layer trunk expansion for large‑scale Aruba‑managed enterprise campus infrastructures
• Top‑of‑Rack 40G uplink pathways connecting Aruba switches to virtualisation and compute server clusters
• Rack‑to‑rack short‑haul multi‑mode fiber connections within Aruba‑equipped server halls
• Enterprise and MSP infrastructure renewal and ArubaOS‑CX network modernisation initiatives
• Multi‑vendor mixed‑fabric deployments for cloud‑native and virtualised workload operations




1. 40G Connectivity for Data Center
High speed, low overhead. The QSFP+ 40G module brings gigabit-class throughput to dense data center racks while drawing less power and taking up less space.



FAQ
Q1: How should operators resolve unsupported‑transceiver alerts after installing HYTOPTODEVICE QSFP+ 40G SR4 on HPE Aruba CX switches? A: This usually means the module's coding does not match the switch's vendor lock. Genuine‑compatible HYTOPTODEVICE modules include the right coding; if the message persists, check the port configuration, update firmware, or contact us for a recode.
Q2: Can HYTOPTODEVICE 40G SR4 transceiver cooperate with current 10G SFP+ infrastructure for phased ArubaOS‑CX network transition? A: Yes, with a breakout solution: the 40G SR4 can be split into 4×10G links using an MPO‑to‑4×LC breakout cable connected to SFP+ ports, letting you migrate gradually.
Q3: Which fiber specifications are mandatory when deploying HYTOPTODEVICE JH231A‑compatible QSFP+ 40G SR4 optical hardware? A: Multimode fiber only — OM3 or OM4 (OM5 also supported on some platforms). It will not work on single‑mode fiber; that requires a 40G LR4 module.
Q4: What power consumption numbers should planners anticipate for HYTOPTODEVICE QSFP+ 40G SR4 inside densely populated Aruba switch racks? A: Typically around 1.0–1.5 W per module, depending on vendor and temperature — far lower than the MSA maximum, so it is safe for dense switch line cards.
Q5: What insertion loss and link‑budget values should be considered while designing Aruba fiber plant for HYTOPTODEVICE 40G SR4 roll‑outs? A: The 40GBASE‑SR4 channel supports a maximum insertion loss of about 1.9 dB (including connectors and patch panels). Confirm your cable plant loss before deployment.
Q6: Will deploying HYTOPTODEVICE 40G SR4 restrict future Aruba network upgrade roadmap moving toward 100G speeds? A: It is a 40G product; the fiber (OM3/OM4) can often be reused for 100G SR4/SR10, but the module and ports must be upgraded. Plan cabling with future capacity in mind.
Q7: Is existing on‑site MPO trunk cabling reusable for HYTOPTODEVICE QSFP+ 40G SR4 within HPE Aruba network projects? A: Check the fiber count, connector polish (UPC), and polarity. Existing 12‑fiber MPO trunks are often reusable, but verify loss and polarity against SR4 requirements.
Q8: What performance impact occurs if mixing OM3 and OM4 multimode fiber segments within one physical link with HYTOPTODEVICE 40G SR4 modules? A: Yes, but the reach is limited by the shorter‑grade segment (OM3), so a mixed link is rated at 100 m maximum.
Q9: What compliance‑related documentation can enterprise buyers obtain for HYTOPTODEVICE factory‑bulk‑ordered QSFP+ 40G SR4 transceivers? A: Typical certifications include CE, FCC, RoHS, and REACH compliance; some suppliers also hold ISO 9001. Ask for certificates before ordering.
Q10: Are HYTOPTODEVICE QSFP+ 40G SR4 modules protected from ESD hazards during shipment and on‑site handling in Aruba environments? A: Yes — they ship in anti‑static packaging and are designed for hot‑swap with ESD protection. Always ground yourself before handling.
Q11: What stock readiness and lead‑time can I expect for HYTOPTODEVICE JH231A‑compatible QSFP+ 40G SR4 factory bulk orders? A: Popular models (Cisco/Arista/Juniper‑compatible 40G SR4) are usually in stock with 24–72 h dispatch; custom‑coded or industrial versions may take 1–3 weeks.
Q12: What payment options and international Incoterm arrangements does HYTOPTODEVICE support for cross‑border factory wholesale QSFP+ 40G SR4 procurement? A: Typical terms: T/T, PayPal, or trade assurance for smaller orders; FOB, CIF, or DDP for freight. Confirm total landed cost (shipping, duties, taxes) before finalizing.
Q13: Are there potential unexpected customs‑related fees when importing HYTOPTODEVICE QSFP+ 40G SR4 for global Aruba enterprise projects? A: Duties and taxes vary by destination and Incoterm. Ask the supplier to quote DDP if you want a fixed, all‑inclusive delivered price with no surprises at customs.
Q14: How to pull real‑time optical diagnostic metrics from HYTOPTODEVICE QSFP+ 40G SR4 running on ArubaOS‑CX / AOS‑S switches? A: Use the switch CLI (e.g., show interface transceiver or show optics) to view per‑lane temperature, voltage, TX/RX power, and alarms — the data comes from the module's standard DOM.
Q15: Does procuring 40G SR4 hardware still deliver practical business value as industry transitions to 100G/400G within HPE Aruba‑managed infrastructures? A: For existing 40G networks it remains fully supported and cost‑effective; your multimode cabling can often be reused later. Choose suppliers with long‑term availability so you can restock for years
Packaging & Custom OEM Solutions
Each QSFP+ SR4 module is individually sealed in ESD-safe anti-static packaging and stocked for same-day dispatch. Bulk orders can also be customized with OEM packaging—logo printing and private labeling included—built for network distributors, system integrators, and enterprise deployments.
Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP+ modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.