• H3C QSFP-100G-LR4L-WDM1300 compatible 100G QSFP28 transceiver module, CWDM4, 2km single mode fibe
  • 100G CWDM4 QSFP28 duplex LC optical module, 3.5W low power DOM monitoring for H3C switches
  • hytoptodevice Zero-alarm 100G QSFP28 transceiver module  for AMPCon-DC leaf spine data center network
  • Bulk wholesale H3C compatible 100G 2km single mode QSFP28 optical transceiver module from hytoptodevice
  • H3C QSFP-100G-LR4L-WDM1300 compatible 100G QSFP28 transceiver module, CWDM4, 2km single mode fibe
  • 100G CWDM4 QSFP28 duplex LC optical module, 3.5W low power DOM monitoring for H3C switches
  • hytoptodevice Zero-alarm 100G QSFP28 transceiver module  for AMPCon-DC leaf spine data center network
  • Bulk wholesale H3C compatible 100G 2km single mode QSFP28 optical transceiver module from hytoptodevice

H3C QSFP-100G-LR4L-WDM1300 Compatible 100G QSFP28 Transceiver | 1310nm(CWDM4) IR4 2KM Module Bulk Wholesale | HYTOPTODEVICE

H3C QSFP-100G-LR4L-WDM1300 compatible 100G QSFP28 IR4 transceiver with 4×25G NRZ signaling. CWDM4 wavelengths 1271/1291/1311/1331nm, 2km OS2 single-mode fiber reach via LC Douplex connector, DDM monitoring, plug-and-play for H3C switches. Reliable bulk supply for data center leaf-spine network upgrades. Small sample testing, private labeling, custom EEPROM coding and OEM available.
NO. Brand  Compatible P/N Remarks
1 Cisco  QSFP-100G-CWDM4-S 
2 Arista Networks  QSFP-100G-CWDM4
3 Brocade  100G-QSFP28-CWDM4-2KM
4 Dell  Q28-100G-CWDM4
5 H3C  QSFP-100G-LR4L-WDM1300
6 HPE Aruba  R0Z30A 
7 Huawei  QSFP-100G-CWDM4
8 Juniper Networks  QSFP-100G-CWDM-T2 
9 NVIDIA(Mellanox)  MMA1L30-CM 
Description
Brocade 100G-QSFP28-CWDM4-2KM Compatible 100G QSFP28 Transceiver | IR4, 4×25G NRZ, 2km Single Mode Fiber

Product Overview

HYTOPTODEVICE 100G QSFP28 CWDM4 IR4 transceiver serves as a pin-compatible replacement for Brocade 100G-QSFP28-CWDM4-2KM.
It uses four-channel CWDM4 wavelength division multiplexing. It delivers steady 103.125Gbps full-rate transmission.
This module targets medium-distance data center interconnection. It operates on four fixed wavelengths: 1271nm, 1291nm, 1311nm and 1331nm.
With 4×25G NRZ modulation, it supports error-free transmission up to 2km over standard OS2 single-mode fiber.
It meets IEEE 802.3bm, CWDM4 MSA and SFF-8636 standards. Built-in DDM tracks optical power, temperature and voltage in real time.
Custom EEPROM enables immediate identification on Brocade hardware without module alarms.
This economical transceiver fits leaf-spine fabric, high-speed server uplinks and campus backbone expansion.
We offer sample testing, customized firmware and flexible bulk pricing for enterprise network projects.

Key Technical Specifications


Brocade Compatible 100G-QSFP28-CWDM4-2KM  Vendor Name HYTOPTODEVICE
Form Factor QSFP28 Max Data Rate 103.125Gbps (4x 25.78Gbps)
Wavelength 1271nm, 1291nm, 1311nm and 1331nm
Max Distance 2km
Connector Duplex LC/UPC Transmitter Type 4 x CWDM DML (DFB)
Cable Type SMF Receiver Type PIN
Modulation (Electrical) 4x 25G-NRZ TX Power -6.5~+2.5dBm
Power Consumption < 3.5W Receiver Sensitivity < -11.5dBm
Protocols QSFP28 MSA, SFF-8636, IEEE 802.3ba, IEEE 802.3bm, CAUI-4 Operation Temperature 0 to 70°C (32 to 158°F)

Usage Guidelines & Best Practices

  • Fiber Matching: This IR4 CWDM4 module requires OS2 single-mode fiber. Multimode fiber leads to heavy attenuation and unreliable links.
  • Port Configuration: Enable RS-FEC on Brocade switch ports. Forward error correction improves stability at the full 2km reach.
  • Installation Tips: Hot plug is supported. Avoid rough insertion to protect gold contacts. Maintain proper fiber bend radius to reduce loss.
  • Distance Limit: This model is designed for 2km links. For connections over 2km, select 100G LR4 transceivers.
  • Operating Environment: Stable operation is guaranteed at 0°C–70°C. Keep away from persistent humidity, dust or extreme heat to extend service life.


Full Compatibility List & Supported Network Hardware

1. Supported Hardware & Firmware

This CWDM4 transceiver is pre-programmed with Brocade matched firmware.
It works plug-and-play on validated Brocade network hardware. It avoids unknown module logs, port instability and link flapping across common firmware releases.
Validated Brocade Device Models:
  • Brocade VDX 6940, VDX 6960 Data Center Switches
  • Brocade ICX 7850, ICX 7750 Enterprise Core Switches
  • Brocade SLX 9150, SLX 9250 High Performance Leaf-Spine Switches
  • All Brocade hardware equipped with standard QSFP28 100G ports

2.Cross-Brand Compatibility

The module follows universal QSFP28 MSA specifications.
It supports interconnection with Cisco, Dell, H3C and other vendor equipment.
It suits mixed-vendor environments and staged network upgrades.

3.Free Value-Added Services

We provide free firmware rewriting and private label customization.
Pre-shipment sample verification and dedicated engineering support are available.
Large-scale deployment orders can access discounted bulk terms to cut total networking expenditure.

Primary Application Scenarios

  1. Data Center Leaf-Spine Fabric: Medium-distance 100G uplinks for Brocade leaf-spine architecture.
  2. Campus Backbone Upgrade: 2km inter-building trunk deployment to replace aging 10G/40G infrastructure.
  3. High Performance Computing: Low-latency links for GPU clusters and large-scale data processing.
  4. Core Network Expansion: Bandwidth upgrade for core and aggregation layers to handle rising concurrent traffic.
  5. Edge Datacenter Interconnection: Cost-effective 100G links between regional edge rooms and central facilities.


Connectivity Solutions(Applications)

1.Leaf-Spine Architecture
 This IR4 module builds reliable 100G leaf-spine links. The 2km coverage supports cross-row and cross-cabinet connections inside data centers. It delivers consistent low-latency forwarding for virtualized and cloud workloads.

100G CWDM4 QSFP28 transceiver for AMPCon-DC management platform leaf-spine data center fabric architecture



2. 100G to 100G for Switch-Switch Interconnection

 It upgrades trunk bandwidth between Brocade core and aggregation switches. It reuses existing single-mode fiber infrastructure and reduces extra cabling work. It raises overall network throughput for growing business traffic.

100G to 100G switch-to-switch trunk link with arista compatible QSFP-100G-CWDM4-S transceive

3.Server NIC High-Speed Uplink

 It creates direct 100G connections between servers and Brocade switches. It satisfies high-throughput requirements for HPC, distributed storage and AI workloads. It improves resource access speed across computing clusters.

100G switch to server adapter card high-speed connection QSFP28 CWDM4 optical transceiver module for data center

The Core Feature 

1.Low Power Consumption, Energy-Saving Operation

Controlled Power Draw for Dense Racks** Maximum power consumption stays below 3.5W. It lowers rack thermal load and helps control data center PUE. Compact QSFP28 form factor supports high-density port layout

3.5W low power high density 100G QSFP28 CWDM4 transceiver for data center high speed transmission

2.Perfect Device Adaptation, Zero-Alarm Operation

Smooth Brocade Recognition, No Alarms** Each batch undergoes real-machine verification on Brocade switches. Custom EEPROM supports hot swap. It runs continuously without identification errors or warning logs
Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation


3.
Strict Full-Round Quality Testing

Rigorous End-of-Line Screening** Every module passes optical parameter calibration and temperature cycling. Bit error rate and long-duration aging tests are mandatory. Consistent batch performance supports 24/7 commercial operation.

Full round quality tested 100G CWDM4 QSFP28 module 24/7 stable operation



FAQ

Q1: Which delivers better TCO, 100G CWDM4 or 100G PSM4 for Brocade data center networking?

A1: Our HYTOPTODEVICE 100G CWDM4 transceiver delivers far higher long-term cost performance than PSM4. PSM4 only supports 500m ultra-short transmission and requires multimode fiber, limiting network layout flexibility. Our Brocade-compatible CWDM4 module extends transmission distance to 2km over standard single-mode fiber. It covers cross-cabinet, cross-row and short inter-building scenarios, eliminating repeated fiber reconstruction and hardware replacement costs for enterprise data center upgrades.

Q2: Why is FEC function mandatory for stable 100G CWDM4 link operation?

A2: FEC is essential for full-distance, error-free CWDM4 transmission. Our 100G IR4 CWDM4 modules adopt strict optical power budget design. Enabling RS-FEC effectively offsets signal loss from fiber splicing, patch cords and long-time aging. It greatly reduces random bit errors and ensures 2km full-load stable operation on all Brocade switch platforms.

Q3: Can Brocade 100G CWDM4 QSFP28 modules support 4×25G breakout mode?

A3: Our standard Brocade 100G CWDM4 transceiver does not support 4×25G breakout mode. It is designed for standard 100G full-rate single-channel transmission, focusing on stable leaf-spine uplink and core trunk networking. For 25G breakout scene requirements, we provide customized breakout-specific optical module solutions to match diverse network deployment needs.

Q4: How to solve module alarm and unrecognized issues on mainstream brand switches?

A4: Most identification errors come from mismatched EEPROM firmware. Our HYTOPTODEVICE modules are pre-flashed with brand-specific customized codes for Brocade, Cisco, Arista and Huawei devices. We support free one-click firmware modification and real-machine testing. It achieves zero-alarm plug-and-play and completely solves port recognition failure and log alarm problems.

Q5: Why do DOM monitoring wavelengths show minor deviations from standard CWDM4 values?

A5: Slight wavelength offset is a normal industry physical feature within MSA standard tolerance. All our Brocade-compatible CWDM4 modules undergo high-precision factory calibration and aging screening. Tiny DOM data fluctuations will not affect actual link speed, transmission stability and equipment service life, ensuring consistent 24/7 commercial operation.

Q6: Are optical attenuators required for ultra-short 100G CWDM4 fiber links?

A6: Ultra-short connections within 3 meters do not require attenuators in most scenarios. Our modules feature optimized optical power output design with strong overload resistance. Only in extreme high-power overload scenarios that cause intermittent link flapping, we provide free matching attenuator configuration guidance to guarantee link stability.

Q7: How to fix persistent low Rx power after standard fiber cleaning?

A7: If fiber cleaning fails to restore normal receiving power, abnormal fiber bending, aging fiber cores or loose port contact are the main causes. Our factory-tested CWDM4 modules maintain ultra-high receiving sensitivity. We provide professional one-on-one technical troubleshooting for bulk clients to quickly locate faults and restore normal 100G link transmission.

Q8: What does -40dBm Rx power in DOM monitoring indicate?

A8: -40dBm means the switch port receives no optical signal, resulting from disconnected fiber, damaged jumpers or remote module failure. Our professional after-sales team provides rapid fault diagnosis. We guide customers in line inspection and module testing to quickly restore data center network business.

Q9: Is there a quality gap between third-party compatible modules and original OEM transceivers?

A9: No actual performance or stability gap exists. Our HYTOPTODEVICE Brocade-compatible modules use industrial-grade laser chips and fully compliant industry protocols. Each batch passes real-machine compatibility testing and full optical parameter calibration. It achieves the same operating effect as original OEM modules with more competitive bulk procurement costs.

Q10: What qualification certifications should be confirmed when purchasing 100G CWDM4 transceivers?

A10: As a professional optical module manufacturer, we provide complete official qualification documents including RoHS environmental certification, MSA/IEEE standard compliance report, high and low temperature cycling test report and real-machine compatibility test records. All products support full-file traceability, ensuring compliant and stable deployment for enterprise and data center projects.

Why Network Engineers Choose HYTOPTODEVICE

HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.

  • Up to 70% cost savings vs OEM, transparent pricing & flexible bulk rates, supported quality returns
  • 100% real-device compatible with Cisco, Huawei,Dell,Juniper, and Arista
  • ISO 9001:2015 Shenzhen factory, full lineup: 1.25G/10G/25G/40G/100G/200G/400G/800G/1.6T transceivers
  • Ample stock, fast global DHL/FedEx shipping in 3–5 working days
  • Free pre-sales engineering support for custom EEPROM  & private label firmware
  • Real switch test videos available for pre-purchase review; inspection & shipping videos provided per order

“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia


Quality Certification & Compliance

 At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.

We adhere to rigorous standards for our SFP modules and network solutions:

  • ISO 9001: Certified quality management and production consistency.

  • CE & FCC: Fully compliant for seamless Global Market Access.

  • RoHS: Committed to environmental responsibility and hazardous material control.

  • Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.

Certified Quality. Global Standards. Guaranteed Performance.




Rigorous Industrial Product Testing

   hytoptodevice check device and equiptment for optical transceiver module

100% 3rd Party Compatible
hytoptodevice 100g qsfp28 sr4 replacement
Partial Test Demonstration
hytoptodevice compatible optical transceiver module for ethernet,data center

Others
HYTOPTODEVICE 100G QSFP28 TRANSCEIVER sr4 application for data center,ethernet

 



 

 

 

  • H3C QSFP-100G-LR4L-WDM1300 compatible 100G QSFP28 transceiver module, CWDM4, 2km single mode fibe
  • 100G CWDM4 QSFP28 duplex LC optical module, 3.5W low power DOM monitoring for H3C switches
  • hytoptodevice Zero-alarm 100G QSFP28 transceiver module  for AMPCon-DC leaf spine data center network
  • Bulk wholesale H3C compatible 100G 2km single mode QSFP28 optical transceiver module from hytoptodevice

Interested in? or Meet any problem?

Enter your contact info, our professional consultant will reach out within 24 hours
FirstName *
LastName *
Email *
Company registered country/region *
Tel/WhatsApp *
Details *

Download

使用HTML,JS,CSS制作页面模块,让你的网站变得更受欢迎