| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | SFP-25G-LR-I | |
| 2 | Arista Networks | SFP-25G-LR-I | |
| 3 | Brocade | 25G-SFP28-LR-I | |
| 4 | NVIDIA(Mellanox) | MMA2L20-AR-I | |
| 5 | Juniper | SFP-25G-LR-IT | |
| 6 | Dell | SFP-25G-LR-I |
| Brocade Compatible | 25G-SFP28-LR-I | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP28 | Max Data Rate | 25Gbps |
| Wavelength | 1310nm | Max Distance | 10km |
| Connector | Duplex LC | Transmitter Type | DFB 1310nm |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | -4.5~+2dBm | Receiver Sensitivity | < -12dBm |
| Max. Power Consumption | ≤1.2W | Receiver Overload | 2dBm |
| Protocols | SFF-8472, SFF-8402, SFF-8432, SFF-8431, CEI-28G-VSR | Operation Temperature | -40 to 85°C (-40 to 185°F) |
Usage Guidelines & Best Practices
Fiber Compatibility: Designed exclusively for G.652 OS2 single-mode fiber. Multimode fibers (OM3/OM4) or incompatible connector polish types (e.g., APC if the module requires UPC) will cause high attenuation and reduce transmission range.
Maintenance & Polarity: Clean LC optical connectors regularly before insertion. Dust and debris on the end face can lead to signal loss and degrade 25GBASE-LR 10KM module performance.
Distance & Link Budget: Supports up to a 10 km transmission distance within the standard optical power budget. Excessive fiber splices, patch panels, or sharp bends will shorten the usable range.
Port Compatibility Check: This optic only works on native 25G SFP28 ports. It can physically insert into SFP+ slots but will not negotiate 25G speed. Confirm your hardware or multi-vendor switch supports 25GBASE-LR standard before plugging in
Industrial Temperature Handling: This industrial-grade module supports -40℃ ~ +85℃ wide-temperature operation. Ensure the cabinet ventilation and heat dissipation are maintained in field deployments; avoid direct exposure to sunlight, moisture, dust or corrosive gas to extend service life.
For detailed operation instructions, please refer to the User Guide.
Full Compatibility List & Supported Devices
1.Validated Brocade Hardware & Firmware
2.Multi‑Brand Cross Interoperability
Features pre-programmed multi-vendor EEPROM compatibility. Rigorously tested to ensure flawless signal transmission, stable link integrity, and full CLI recognition across diverse switch and router ecosystems.
3.Free Value-Added Services
Custom EEPROM programming for multi-platform compatibility
Pre-bulk sample testing for project validation
Private label customization and deployment guides
Strict batch quality control
EEPROM configuration for legacy network environments
Free EEPROM recoding plus 24/7 technical support
Primary Application Scenarios
Connectivity Solutions(Applications)

The Core Features
1. Low Power & High Port Density

2. Host Validated for Reliable Interoperability
Each SFP28 25G transceiver plugs into target host switches directly without unsupported transceiver alarms and reduces project debugging time. Specific Compatibility Video available upon request.


Q1: What type of laser source is fitted inside this industrial 25G SFP28 LR module for 1310nm optical transmission? A: YES. HYTOPTODEVICE equips this SFP28 25G LR module with genuine DFB laser tailored for 1310nm transmission, delivering stable optical power for 10km single-mode fiber links.
Q2: Can this 25G transceiver run at reduced 10G SFP+ LR speed or auto adapt to older 10G ports? A: NO. This is a native 25GBASE-LR SFP28 transceiver. It cannot auto-negotiate or drop down to 10G SFP+ LR speed, and only works on 25G SFP28 host ports.
Q3: Could bench testing with very short fiber patch cords lead to permanent hardware damage of the receiver photodiode? A: NO. It will not burn the hardware. The module’s maximum transmit power (Max Tx = +2 dBm) does not exceed the receiver overload threshold (+2 dBm). Direct connection with short patch cables will not exceed the receiver’s physical limit and cause permanent hardware damage. Even though permanent hardware burnout will not happen, testing over extremely short fiber without an attenuator may force the receiver into optical saturation. This triggers signal distortion, high BER and intermittent link flap. Dirty short patch cords may also introduce reflection and degrade DFB laser stability. A fixed 3~5dB optical attenuator is recommended for bench testing to achieve optimal signal quality.
Q4: Is the target BER performance maintained across the full industrial temperature range from -40℃ up to +85℃? A: YES. Our 3-temperature aging test verifies this industrial SFP28 transceiver keeps the specified BER performance across the full -40℃ ~ +85℃ industrial operating temperature range.
Q5: Does the transmitter’s eye diagram meet IEEE 802.3cc mask requirements with adequate design margin? A: YES. Every finished module passes eye diagram testing, meeting IEEE 802.3cc mask specifications with adequate margin to guarantee stable long-run transmission.
Q6: How does laser efficiency behave when operating continuously near the maximum rated temperature of +85°C? A: Laser efficiency drops slightly at +85℃. HYTOPTODEVICE’s factory calibration compensates for this thermal effect, so the module still meets full 25GBASE-LR performance at maximum rated temperature.
Q7: Is the module housing hermetically sealed to stop moisture and condensation forming internally? A: NO. The module is not hermetically sealed. It supports operation under high-humidity environments, but direct condensation on the optical interface should be avoided for reliable operation.
Q8: Can the module latch withstand continuous vibration in demanding deployments such as cell towers and rail sites? A: YES. The robust latch design is validated for high-vibration scenarios such as cell towers and railway sites, preventing accidental module disconnection during vibration.
Q9: Can the preloaded EEPROM code bypass the built-in third-party optic lock found on popular vendor network hardware? A: YES. HYTOPTODEVICE custom-programs EEPROM for Brocade and other major brands, to bypass vendor third-party optic lock and enable plug-and-play recognition on supported host hardware.
Q10: Does this industrial SFP28 optic satisfy SFF-8402 and SFF-8432 mechanical and electrical requirements? A: YES. This industrial SFP28 25G LR transceiver fully complies with SFF-8402 and SFF-8432 mechanical & electrical specifications, ensuring interoperability with standard SFP28 host ports.
Q11: Does the Rate Select pin logic function reliably across different brands of host switches and routers? A: YES. Rate Select pin logic is fully calibrated. It maintains consistent behavior across multiple host platforms to avoid rate negotiation faults during deployment.
Q12: Apart from standard Ethernet traffic, can this optic carry CPRI/eCPRI signals for 5G base station fronthaul links? A: YES. This HYTOPTODEVICE industrial optic supports CPRI/eCPRI pass-through for 5G fronthaul, in addition to standard 25G Ethernet transmission.
Q13: Where do we source the DFB laser and ROSA receiver components used for these 25G industrial transceivers? A: YES. We source DFB laser and ROSA assemblies from Tier 1 optical component makers, which guarantees consistent performance and long service life for bulk buyers.
Q14: What proof can purchasers obtain to confirm these are genuine industrial modules instead of relabeled commercial grade optics? A: Buyers can verify via our 3-temperature aging test reports and DDM log data. HYTOPTODEVICE provides full test documentation to prove these are true industrial grade modules, not relabeled commercial versions.
Q15: What creates the large price gap between our industrial transceivers and low-cost generic alternatives from other suppliers? A: The main difference lies in component grade, 3-temperature full aging test, raw chip sourcing and QC workflow. HYTOPTODEVICE factory-grade industrial transceivers adopt Tier1 chips and complete 3-temperature testing, delivering much lower field failure rates than cheap alternatives.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.