| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | QSFP-100G-ER4L-S | |
| 2 | Arista Networks | QSFP-100G-ERL4 | |
| 3 | Dell | Q28-100G-ER4-lite | |
| 4 | Huawei | QSFP-100G-ER4-Lite | |
| 5 | Juniper Networks | QSFP-100G-ER4L | |
| 6 | Ruijie Networks | 100G-QSFP-ER4-SM1310 | |
| 7 | HPE Aruba | JL743A | |
| 8 | Brocade | 100G-QSFP28-ER4-40KM | |
| 9 | Ciena | XCVR-Q30V31 | |
| 10 | EdgeCore | ET7402-ER4 |
| Brocade Compatible | 100G-QSFP28-ER4-40KM | Vendor Name | HYTOPTODEVICE |
| Form Factor | QSFP28 | Max Data Rate | 103.125Gbps |
| Wavelength | 4 x LAN WDM (1295、1300、1305、1310nm) | Max Distance | 30km without FEC 40km with FEC |
| Connector | Duplex LC | Transmitter Type | 4 x LAN WDM EML |
| Cable Type | SMF | Receiver Type | APD |
| TX Power | -2.5~+4.5dBm | Receiver Sensitivity | <-16.9dBm without FEC <-20.9dBm with FEC |
| Protocols | 100G Ethernet, MSA Compliant | Power Consumption | < 4.0W |
Usage Guidelines & Best Practices
Fiber Choice: Works only with OS2 single-mode fiber. Multimode fiber is not compatible with this 1310nm CWDM4 module.
Optical Attenuator Required for Short Links: For testing or short-distance connections (<15km), connect a 10dB–15dB optical attenuator to the RX port to prevent damaging the receiver.(15KM
Cleanliness & Dust: Keep dust caps on whenever unattached. Clean fiber end-faces with a optical cleaning pen before insertion; dust causes over 80% of optical link failures.
Installation Specification: Hot-swap supported. Follow ESD anti-static procedures and keep LC connectors clean for stable links.
Operating Environment: 0°C–70°C commercial temperature range. Ensure cabinet ventilation to avoid optical power attenuation from overheating.
Full Compatibility List & Supported Network Hardware
1.Native Brocade Compatibility


The Core Features
1.Broad 100G Data Center Applicationg
Supports reliable, high-efficiency long-haul data transmission between core and spine network layers, fully satisfying deployment requirements for large-scale data centers.
2. 100G High-Speed Data Center Connectivity

3. Host-Tested for Proven Interoperability
Every module undergoes rigorous compatibility validation on target host switches, ensuring stable, error-free operation in your live network environment.Specific Compatibility Video available upon request.


Q1: Will Brocade 100G‑QSFP28‑ER4‑40KM replacement QSFP28 ER4 Lite work inside legacy 40G‑capable QSFP+ slots? A: It will not establish valid links in QSFP+ 40G slots. This HYTOPTODEVICE Brocade‑compatible ER4 Lite is hardware‑locked to 100Gbps line‑rate and lacks rate‑downshift function. Network integrators must use native QSFP28 100G ports on Brocade SLX/VDX hardware to achieve full 100GBASE‑ER4L performance.
Q2: What performance gaps exist between ER4 Lite and full‑spec ER4 when sourcing compatible Brocade 100G optical modules for metro projects? A: ER4 Lite delivers identical 40km maximum reach with 0.5‑1W lower power draw versus full‑spec ER4. Tested under HYTOPTODEVICE lab conditions, ER4 Lite keeps bit error rate below 1E‑12 across the whole temperature range. Distributors can recommend this cost‑optimized variant for metro deployments that do not require extended power budget beyond 40km.
Q3: Can this Brocade compatible 100GBASE‑ER4L optic operate over dual‑core OS2 single‑mode fiber for cross‑campus backbone builds? A: Yes, this HYTOPTODEVICE QSFP28 ER4 Lite requires two OS2 single‑mode fiber cores for bidirectional 100G traffic. LAN‑WDM four‑channel wavelengths are multiplexed inside one transceiver housing. Procurement teams should confirm duplex fiber availability during site survey before ordering bulk quantities of these compatible transceivers.
Q4: Is OM multimode fiber acceptable when deploying Brocade 100G‑QSFP28‑ER4‑40KM equivalent transceivers for long‑distance inter‑building links? A: Multimode fiber cannot satisfy this 40km transmission requirement. Even high‑grade OM4 multimode has excessive modal dispersion, limiting 100G reach to only 100‑150 meters. HYTOPTODEVICE recommends end‑users deploy OS2 single‑mode fiber exclusively, which wholesalers can bundle together with transceiver orders for complete project kits.
Q5: Why is the 1310nm LAN‑WDM band selected for Brocade 40km 100G metro compatible transceivers? A: LAN‑WDM 1295‑1309nm window exhibits typical 0.22dB/km attenuation on OS2 fiber. HYTOPTODEVICE calibrates each laser channel to this wavelength grid, ensuring consistent optical budget for 40km runs. System integrators benefit from low signal loss without resorting to expensive C‑band DWDM components for enterprise metro links.
Q6: Are optical attenuators mandatory for short‑haul runs under 10km with Brocade compatible QSFP28 ER4‑Lite 100G transceivers? A: Attenuators are mandatory for links shorter than 10 km. Our module TX output ranges from ‑2.5~+4.5dBm and receiver overload threshold is ‑3.5dBm; unattenuated short links will exceed overload threshold. HYTOPTODEVICE advises buyers to deploy 10‑15dB duplex LC attenuators to prevent receiver saturation and maintain stable link performance for short rack‑to‑rack applications.
Q7: How much chromatic dispersion margin is reserved on HYTOPTODEVICE Brocade‑compatible 100GBASE‑ER4‑Lite modules for real‑world 40km fiber routes? A: Each unit is pre‑characterized for OS2 fiber chromatic dispersion up to 40km distance. Our factory burn‑in test simulates real‑world fiber dispersion conditions, keeping post‑FEC bit‑error‑rate well under 1E‑12. This provides safety margin for splice and connector losses frequently encountered in integrator‑managed leased‑fiber projects.
Q8: What hardware damage risks arise from excessive incoming optical power on drop‑in Brocade 100G QSFP28 ER4 Lite replacement parts? A: Excessive receive power can permanently degrade the internal photodiode receiver. Field statistics collected by HYTOPTODEVICE RMA data show roughly 60% of returned long‑reach copper‑free 100G transceivers stem from unattenuated short‑link operation. Distributors should pass power‑matching deployment guidance along to their end‑customer technical teams.
Q9: What ambient operating conditions apply to commercial‑grade Brocade 100G‑QSFP28‑ER4‑40KM alternative transceivers from HYTOPTODEVICE? A: Standard commercial SKU reliably operates from 0℃ to +70℃ cabinet ambient. Every HYTOPTODEVICE unit passes 8‑hour high/low‑temperature cycling during production QA. Wholesalers with outdoor cabinet tenders may inquire about our industrial‑grade ‑40~+85℃ variant for non‑climate‑controlled field hardware deployments.
Q10: Do HYTOPTODEVICE Brocade‑compatible QSFP28 ER4‑Lite transceivers adhere to global MSA and IEEE specifications for third‑party 100G switch optics? A: Yes, all electrical, mechanical and optical parameters follow IEEE 802.3 and QSFP28 MSA SFF‑8665 standards. Full DDM/DOM monitoring registers follow MSA defined memory map. This compliance enables system integrators to mix‑and‑match alongside other MSA‑compliant optics inside multi‑vendor network fabrics.
Q11: What compliance documentation is supplied when purchasing bulk quantities of Brocade‑compatible 100G QSFP28 ER4‑Lite transceivers? A: Each bulk shipment includes CE, FCC, RoHS compliance certificates plus batch‑specific optical test reports. HYTOPTODEVICE exports complete document sets assisting customs clearance and enterprise project audit requirements. Global resellers can request additional declaration forms to satisfy regional import regulatory constraints.
Q12: What warranty and advanced‑replacement terms apply for project‑scale bulk orders of HYTOPTODEVICE Brocade replacement 100G transceivers? A: Standard factory warranty covers early‑life hardware defects with fast advanced‑replacement logistics. High‑volume system‑integrator projects qualify for priority stock reservation. Distributors with recurring quarterly procurement volumes can open dedicated support tickets to accelerate RMA processing for their end‑client sites.
Q13: What preventive maintenance work should operators perform on deployed 40km 100GBASE‑ER4L Brocade‑compatible transceivers? A: Visual port cleaning and insertion‑loss spot‑check every 6‑12 months is recommended. Contaminated LC end‑faces account for many slow‑degrading intermittent faults. HYTOPTODEVICE suggests network operators integrate DDM power‑threshold alerts as part of routine O&M workflows for metro backbone infrastructure.
Q14: Can HYTOPTODEVICE Brocade‑compatible QSFP28 ER4‑Lite modules deliver stable links across 25‑30km intermediate‑reach data‑center interconnect routes? A: Yes, the module provides ample optical power margin for 25‑30km DCI applications. Our internal test results confirm stable error‑free operation even after adding 3‑4dB cumulative splice‑and‑connector loss. This makes the part attractive for procurement teams handling geographically separated campus data‑center interconnection projects.
Q15: Are third‑party compatible 100GBASE‑ER4‑Lite QSFP28 transceivers suitable for carrier‑leased dark‑fiber metro circuits on Brocade hardware? A: Yes, HYTOPTODEVICE MSA‑compliant ER4‑Lite works on standard OS2 leased dark‑fiber circuits. Our engineering team offers complimentary link‑budget calculation support for system‑integrator carrier‑customer bids. Always verify total fiber loss before deployment to avoid marginal‑link issues on operator‑provided metro fiber paths
Packaging & Custom OEM Solutions
ESD Protection & Fast Shipping: Every module is sealed in an ESD-safe bag and ready for same-day dispatch from stock.
Custom OEM & Branding: We provide logo printing, private labeling, and custom packaging to help distributors and integrators build their brand—no factory investment required.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.