| NO. | Brand | Compatible P/N | Transceiver Type |
| 1 | Cisco | GLC-BX80-DA | |
| 2 | Cisco | Cisco GLC-BX80-DA-I | |
| 3 | Brocade | E1MG-1G-BXD-80 | |
| 4 | Dell | SFP-GE-BX80-1550 | |
| 5 | Extreme | MGBIC-BX80-U | |
| 6 | H3C | SFP-GE-LH70-SM1550-BIDI | |
| 7 | HPE H3C | SFP-1G-BXD-80 | |
| 8 | Huawei | SFP-GE-ZBXD1 | |
| 9 | Juniper | SFP-GE80KT15R14 | |
| 10 | MikroTik | S-4554LC80D-1550 | |
| 11 | Netgear | SFP-GE-BX80-D |
| Cisco Compatible | GLC-BX80-UA-I | Vendor Name | HYTOPTODEVICE |
| Form Factor | SFP | Max Data Rate | 1.25Gbps |
| Wavelength | TX1490nm/RX1550nm | Max Distance | 80km |
| Connector | Simplex LC | Transmitter Type | 1490nm DFB |
| Cable Type | SMF | Receiver Type | PIN |
| TX Power | 0~5dBm | Receiver Sensitivity | < -26.0dBm |
| Protocols | SFF-8472 MSA Compliant, IEEE 802.3ah-2004 | Operation Temperature | -40 to 85°C (-40 to 185°F) |
Complementary Pairing: BiDi transceivers must be deployed in matched pairs (e.g., TX1490/RX1550 with TX1550/RX1490). Mismatched wavelengths cannot establish a link.
Fiber Choice: Use Single-Mode Fiber (SMF) only. Do NOT use MMF.
Connector Match: Simplex LC (UPC/PC polish only). Do NOT use Duplex LC or APC.
Laser Safety: Class 1 Laser. Never look directly into optical ports or fiber end-faces.
ESD Safety: Wear an anti-static wrist strap before handling the transceiver.
Cleanliness & Dust: Keep dust caps installed on all unused ports. Clean fiber connectors with an optical cleaning pen before insertion; dust causes over 80% of link failures.
Optical Attenuator Required: For short-distance testing or links (<20 km), connect a 10dB–15dB attenuator to the RX port to prevent receiver damage.
Installation & Hot-Swap: MSA compliant. Insert and remove gently without powering down the device.
High Loss / Packet Drops: Ensure fiber bend radius exceeds 30 mm, inspect optical power levels, and clean connectors.
No Link: Verify complementary BIDI wavelength pairing requirement; clean Simplex LC end-faces; check port speed configuration.
1. Supported Hardware & Firmware








Q1: Will this industrial‑grade BiDi SFP work on my existing Cisco or third‑party brand network hardware? A1: Yes, it is compatible with qualified mainstream switches and routers. Pre‑flashed Cisco‑matched EEPROM enables plug‑and‑play on Cisco IOS devices; custom EEPROM programming is needed for Huawei, H3C, Juniper, Dell platforms. Conduct sample verification before large‑volume project procurement to prevent transceiver identification alarms.
Q2: Can I install this 1.25G industrial BiDi SFP into a 10G‑rate SFP+ hardware port? A2: Most 10G SFP+ ports support backward compatibility for 1.25G SFP, but you need manually force port speed to 1G on your switch configuration. Physical insertion fit cannot guarantee auto‑negotiation success, manual speed setting is mandatory to obtain stable gigabit link.
Q3: Is it feasible to pair this Tx1490/Rx1550 BiDi unit with ordinary dual‑fiber gigabit SFP modules? A3: No, mixing these two module types cannot bring up usable network link. This BiDi leverages WDM wavelength multiplexing over one fiber strand, whereas dual‑fiber SFP transmits on two independent fibers. Always use matched reverse‑wavelength BiDi transceiver pairs instead of mixing dual‑fiber optics.
Q4: What network failure symptom will appear if installing two same‑wavelength industrial BiDi modules at both link ends? A4: You will see no link status and LOS alarm triggered on connected network equipment. Both ends transmit at 1490nm and receive at 1550nm without wavelength cross‑match. One side needs Tx1490/Rx1550 and opposite side must adopt Tx1550/Rx1490 to finish bidirectional WDM transmission.
Q5: How do field‑site technicians distinguish Tx1490 from Tx1550 BiDi module on‑site? A5: Read the printed marking text on SFP module outer housing. Every industrial BiDi SFP has clear Tx/Rx wavelength printed label. Do not judge only by latch color; double‑check printed wavelength information before field‑site wiring to avoid wrong pairing errors.
Q6: Which fiber patch‑cable specification is required when deploying this industrial BiDi transceiver in outdoor projects? A6: You have to deploy simplex LC OS1 / OS2 single‑mode fiber patch cords. Duplex‑LC and multimode fiber cable are not suitable for single‑strand BiDi 80km transmission. Clean simplex‑LC connector end‑faces before connection to cut insertion loss and reduce intermittent LOS risks for long‑distance field‑site links.
Q7: What optical chip composition is adopted on this 80km industrial BiDi SFP for harsh‑environment deployment? A7: This industrial BiDi SFP equips DFB laser transmitter together with PIN receiver. PIN receiver achieves receiving sensitivity down to‑26 dBm. This mature chip combination keeps stable optical performance under wide‑temperature‑range 80km single‑mode fiber transmission.
Q8: What link‑budget performance can I expect for this industrial‑grade 80km BiDi transceiver under field‑site conditions? A8: Our module delivers TX output 0‑5 dBm and RX sensitivity better than‑26 dBm, providing minimum 26 dB link budget. Typical single‑mode fiber attenuation reaches approx 0.25 dB/km within 1490‑1550nm window. Reserve loss margin for field‑site splices and connector joints; keep overall loss within 26 dB to guarantee full‑distance stable running.
Q9: Does industrial wide‑temp BiDi SFP consume much more power compared with commercial‑grade short‑reach BiDi modules? A9: No, power consumption remains well‑controlled below 1W. This industrial unit uses DFB laser and PIN receiver chipset. It fully complies with SFP MSA power specification and will not overload standard SFP host ports.
Q10: For outdoor industrial‑site projects, what are the core merits selecting single‑fiber BiDi SFP versus conventional dual‑fiber optical modules? A10: BiDi SFP halves fiber‑core occupancy especially for field‑sites with limited fiber resources. It uses WDM technique for bidirectional signal transmission over only one fiber strand. It is well‑suited for remote‑site backhaul, outdoor surveillance and industrial renovation where laying extra fiber pairs costs heavily.
Q11: Can I deploy this industrial BiDi transceiver within existing CWDM or DWDM multiplexing network infrastructure? A11: It is not suggested to use this module in standard CWDM / DWDM systems. Its fixed 1490/1550nm wavelengths overlap common CWDM channel spectrum. Choose CWDM‑specific qualified optical transceivers if wavelength‑multiplexing networking is required for your industrial project.
Q12: What warranty coverage can buyers obtain when sourcing this industrial BiDi SFP for bulk project orders? A12: HYTOPTODEVICE provides standard 5‑year factory warranty for manufacturing defects. Warranty applies to hardware failure occurring under rated‑40℃~85℃ industrial operating conditions; damage caused by ESD shock, contaminated fiber end‑faces, optical overload and improper field‑site handling falls outside warranty coverage.
Q13: Why is industrial‑grade 80km BiDi SFP higher‑priced than 10km or 20km commercial BiDi SFP products? A13: High‑power DFB/EML lasers, high‑sensitivity PIN receivers, and tight wavelength isolation filters drive up manufacturing costs. Short‑reach BiDi modules can adopt lower‑grade optical components. Additional wide‑temperature calibration and temperature‑cycling burn‑in testing for industrial usage further increase production expense.
Q14: Troubleshooting guide: How should engineers handle Rx Power Low or LOS alarms popping up on industrial field‑site network switches? A14: Start troubleshooting from physical‑layer connections in field‑site environment. Clean simplex‑LC patch‑cord end‑faces, reseat SFP transceivers, double‑check BiDi wavelength pairing status and test total link optical loss. If measured loss exceeds module power budget, shorten transmission distance or deploy fiber amplifier for long‑haul single‑fiber links.
Q15: What major root factors trigger intermittent link flapping for industrial‑site BiDi SFP single‑fiber links? A15: Link flapping mostly originates from physical‑layer faults associated with the PIN receiver. Common causes include polluted fiber end‑faces, insufficient receiving optical margin, reversed wavelength pairing, ESD‑damaged PIN receiver or abnormal temperature inside outdoor cabinet. Check DDM real‑time optical power and temperature reading to quickly pinpoint fault sources.

Why Network Engineers Choose HYTOPTODEVICE
HYTOPTODEVICE has supplied over 5000,000 optical transceiver modules to data centers, ISPs, and enterprise networks across 100+ countries since 2011. Every module undergoes a 72-hour burn-in test and full DDM/DOM validation before shipment.
“Phenomenal performance. We deployed 200 HYTOPTODEVICE SFP modules to replace Cisco OEMs in our backbone network. Result? Zero compatibility issues and a 60% reduction in costs. Highly recommended for mission-critical networks."— Senior Network Engineer, Regional Telecom, Australia
Quality Certification & Compliance
At HYTOPTODEVICE, our quality commitment is backed by industry-standard validations. From fiber optical transceiver manufacturing to final visual inspection, from IQC、IPQC、FQC to OQC, our processes ensure global compliance and reliability.
We adhere to rigorous standards for our SFP modules and network solutions:
ISO 9001: Certified quality management and production consistency.
CE & FCC: Fully compliant for seamless Global Market Access.
RoHS: Committed to environmental responsibility and hazardous material control.
Proven Reliability: Rigorous testing to reduce compliance risk and ensure safety.
Certified Quality. Global Standards. Guaranteed Performance.